Adult Head (Hematoma) for X-Ray CT, US, MRI
Product Description
The Adult Head (Hematoma) phantom is a specialized medical training solution designed for skill development in applications relating to head trauma and hematomas. It replicates the intricate anatomy of the human head and is fully compatible with X-Ray CT, Ultrasound, and MRI. The phantom is ideal for refining expertise in clinical scenarios involving stroke, aneurysms, and various head injuries in a risk-free environment.
For MRI, the tissues offer realistic T2 relaxation time values, making the phantom highly suitable for T2-weighted and proton-density imaging methods. It is compatible with multiple contrast mediums, including Barium-sulfate, Iodine, Gadolinium, Microbubble, and Iron Oxide-based products. The materials are stable over time and engineered for long-term use.
Note: By default, the phantom comes in a translucent amber appearance. A skin feature can be included upon request. Protective urethane coating increases body tissue hardness by approx. 30 points (e.g., from OO 60 to OO 90).
Anatomy
- Skull: Realistic three-layered bone structure.
- Cervical Spine: Realistic vertebrae included.
- Brain: Grey Matter parenchyma, Falx Cerebri, and Brain Ventricles.
- Pathology: Realistic Hematoma feature.
- External: Alignment markings and acoustically correct skin-mimicking material.
Head Phantoms Comparison
| Features | Hematoma Head | Standard Head | Training, V1 Head | Static Head |
|---|---|---|---|---|
| Skull | ? | ? | ? | ? |
| Hematoma | ? | ? | ? | ? |
| Cervical Spine | ? | ? | ? | ? |
| Brain Ventricles | ? | ? | ? | ? |
| Falx Cerebri | ? | ? | ? | ? |
| Brain (Gray Matter) | ? | ? | ? | ? |
| Skin Mimicking Material | ? | ? | ? | ? |
| Alignment Markings | ? | ? | ? | ? |
Technical Properties
| Type of Tissue | Sound Velocity [m/s] | Density [g/cm³] | Attenuation (2.25 MHz) [dB/cm] | Hardness [Shore 00]* | T2 [ms] | Speckles |
|---|---|---|---|---|---|---|
| Cortical Bone | 3000 ± 30 | 2.31 | 6.4 ± 0.3 | N/A | N/A | N/A |
| Trabecular Bone | 2800 ± 50 | 2.03 | 21 ± 2 | N/A | N/A | N/A |
| Brain Matter | 1400 ± 10 | 0.99 | 1.0 ± 0.2 | 20 | 70 | YES |
| Hematoma | 1400 ± 10 | 0.99 | 1.0 ± 0.2 | 20 | 70 | NO |
| Skin/Body Tissue | 1400 ± 10 | 1.02 | 1.7 ± 0.2 | 60 | 50 | NO |
*Measured without protective coat; coating increases hardness by approx. 30 points.
HU Values of Tissue-Mimicking Materials
| S.No. | Tissue Type | HU Value (average) |
|---|---|---|
| 1 | Brain Tissue | -25 |
| 2 | Trabecular Bone | 800 |
| 3 | Cortical Bone | 1300 |
| 4 | Skin Tissue | -25 |
Included in Order
- Adult Head (Hematoma) Phantom
- User Manual / Assembly Instructions
- 2-Year Warranty & Unlimited Customer Service
- Hard Carry Case
Size & Weight
Phantom: 12 x 9 x 7 Inches | Weight: ~17 Lbs
Shipment: 23 x 14 x 10 Inches | Weight: ~22 Lbs
Materials Used
- Soft tissue and organs: Composition of urethane-based soft resin
- Synthetic bones: Patented ceramic-reinforced epoxy-based composite material
Customization
This phantom can be customized upon special request to mimic additional pathologies such as stroke, swelling, or aneurysms.
Warranty Information
2-Years Limited Warranty Against Manufacturer Defects
True Phantom Solutions Inc. (TPS) Products Limited Warranty
The TPS products are guaranteed to be free from defects in material and workmanship, under normal use, for a period of two years after date of shipment. This warranty covers the repair or replacement of a product when is sent prepaid to TPS. TPS does not assume liability for installation, abuse, alteration, insufficient application data provided for a design or misuse. We are responsible for the condition of our product. We would love to help you resolve any issues. Please let us know if you have received any defective items by contacting us here: [email protected]
Who qualifies?
TPS customers who buy directly from True Phantom Solutions Inc.. Products purchased from other third-party sellers are NOT eligible for TPS limited warranty. Purchased from other channels may offer different or altered warranties.
What qualifies?
Valid only for items with manufacturer defects, flaws produced by a manufacturer error, or defects caused during production. Products must be in their original storage case (if provided) or one with comparable protection.
Returns/Replacements
Any product requiring a return/replacement (for warranty or non-warranty repair) requires pre-approval from Anatomy Warehouse prior to shipment. Contact Anatomy Warehouse customer service department at 800-422-1134 or [email protected] in order to obtain a RPA (Return/Replacement Product Authorization) number. The RPA number should be clearly marked on the returned package label and your packing list, or shipping document. Return product freight prepaid in its original storage case (if provided) or one with comparable protection. True Phantom Solutions will not accept return shipments sent freight collect. Product damage incurred during return shipment, from poor packing, will not be warranted by True Phantom Solutions.